Electronic Energy Efficiency
Immunity EMI test

Most global markets require EMC emission compliance certification; Currently, the EU is the only major market that also requires EMI certification. Products intended for sale in the European market must comply with EN and IEC standards that specify EMC immunity performance.
Electrostatic Discharge
+/-15 kV contact discharge,+/-30 kV air discharge;
? Temperature and humidity controlled laboratory;
Static target, 1GHz oscilloscope;
Regarding standard IEC/EN testing and various electrostatic discharge heads specifically designed for the automotive industry.
High current injection (BCI)
Use bidirectional power meters and probes for forward, reverse, and net power measurements in each test;
Specially designed equipment to improve repeatability accuracy;
Specific equipment that meets testing standards (aimed at ensuring correct testing and repeatability accuracy);
Can be tested according to Ford, General Motors, Chrysler, Fiat, Nissan, Honda, Mazda, Audi, ISO or any other BCI standards.
Radiated electromagnetic field (RF)
A uniform magnetic field that complies with IEC/EN standards;
Modulation type (AM, FM, pulse);
For field strengths designed for>600 V/m, ranging from 1 meter CW or pulse 1 to 18GHz;
Provide a calibration site with a maximum frequency of 18 GHz;
1kW amplifier, 80 MHz to 1 GHz;
250W amplifier, 1 GHz to 18 GHz;
500W amplifier, 10 kHz to 200 MH;
5M EMC laboratory - capable of conducting tests from 26 MHz to 18 GHz. Can be used for testing according to the following standards: SAE, ISO, General Motors, Ford, Chrysler, Nissan, Audi, Fiat, Honda, Mazda; CISPR 25、11、16、22,SAE J1113、SAE J551;
General industrial standards, including automotive, General Motors 5097, 3100 DC 10614REV A、 Ford AB/AC、 Nissan, Mazda, Fiat, Honda, Audi, Chrysler SAE、ISO、 Mazda;
? Provides peripheral support tools: compressed air (125 PSI @ 30 CFM, coated or purified @ 2 microns, water (up to 100 PSI), external air outlet (200 CFM), AC power supply - maximum 240 VAC @ 50 Amps (50 or 60 Hz) single-phase or three-phase, DC power supply - maximum 65 VDC @ 150 Amps. Full color internal monitoring system, providing multiple camera angles. We can also provide generators, coolers, power loads, inert gases, and EMC enhanced computers.
EUT (Equipment Under Test) can be a desktop or floor standing device.
Scope | EN standard | IEC standard |
Electrical Fast Transient Pulse Swarm Immunity | EN 61000-4-4 | IEC 801-4; IEC 61000-4-4 |
Conducted continuous interference from DC to 150 kHz | EN 61000-4-16 | IEC 61000-4-16 |
Conducted interference induced by radio frequency field | EN 61000-4-6 | IEC 61000-4-6 |
Electrostatic Discharge | EN 61000-4-2 | IEC 61000-4-2 |
General Immunity - Industrial Environment | EN 61000-6-2 | IEC 61000-6-2 |
General Immunity - Residential, Commercial, and Light Industrial | EN 61000-6-1 | IEC 61000-6-1 |
Magnetic field, damping oscillation wave | EN 61000-4-10 | IEC 61000-4-10 |
Magnetic field, ringing wave | EN 61000-4-12 | IEC 61000-4-12 |
Power frequency magnetic field | EN 61000-4-8 | IEC 61000-4-8 |
Pulse magnetic field | EN 61000-4-9 | IEC 61000-4-9 |
Pulse magnetic field | EN 61000-4-3 | IEC 61000-4-3 |
surge | EN 61000-4-5 | EN 61000-4-5 |
Voltage dip, short interruption, and voltage variation | EN 61000-4-11 | IEC 61000-4-11 |
Standard Number Standard Name
DB33/T334 Safety Technology Prevention (System) Engineering Inspection Specification
GB 16796 Safety Requirements and Test Methods for Security Alarm Equipment
GB 50339 Code for Quality Acceptance of Intelligent Building Engineering
GB 50348 Technical Specification for Security and Prevention Engineering
GB 8702 Electromagnetic Radiation Protection Regulations
GB 9175 Environmental Electromagnetic Wave Health Standard
GB/T 12190 Measurement Method for Shielding Efficiency of Electromagnetic Shielding Room
GB/T 15541 Measurement Method for Transmitting Frequency
GB/T 2887 General Specification for Computer Sites
SJ/T 10694 Test Method for Anti static Systems in Electronic Product Manufacturing
Please consult NormalTCI for specific questions
National Unified Service Hotline: 400-6177-880
Email: service@normaltci.com
Copyright @ 2015 NORMAL (HANGZHOU) TESTING & CERTIFICATION CO., LTD.
Tell:+86-571-28906690 E-mail:service@normaltci.com Service Hotline:400-6177-880 Fax:+86-571-28867000
If you have any comments on the website, please email to:service@normaltci.com