亚洲一区高清无码_国产精品无码天堂2021_久久久这里有的精品_国产v亚洲v天堂a手机版_日本中出人妻专区中文字幕

Hello,Welcome to Normal Website!

Service Items

Contact US

Tell:+86-571-85691658
Fax:+86-571-28867000
E-mail:service@normaltci.com
Address:North block, 9 block,, Jiangling, Binjiang District, Hangzhou, Zhejiang

Electronic Energy Efficiency

HOME>>Electronic Energy Efficiency

Immunity EMI test

Most global markets require EMC emission compliance certification; Currently, the EU is the only major market that also requires EMI certification. Products intended for sale in the European market must comply with EN and IEC standards that specify EMC immunity performance.

 

Electrostatic Discharge

 

+/-15 kV contact discharge,+/-30 kV air discharge;

 

? Temperature and humidity controlled laboratory;

 

Static target, 1GHz oscilloscope;

 

Regarding standard IEC/EN testing and various electrostatic discharge heads specifically designed for the automotive industry.

 

High current injection (BCI)

 

Use bidirectional power meters and probes for forward, reverse, and net power measurements in each test;

 

Specially designed equipment to improve repeatability accuracy;

 

Specific equipment that meets testing standards (aimed at ensuring correct testing and repeatability accuracy);

 

Can be tested according to Ford, General Motors, Chrysler, Fiat, Nissan, Honda, Mazda, Audi, ISO or any other BCI standards.

 

Radiated electromagnetic field (RF)

 

A uniform magnetic field that complies with IEC/EN standards;

 

Modulation type (AM, FM, pulse);

 

For field strengths designed for>600 V/m, ranging from 1 meter CW or pulse 1 to 18GHz;

 

Provide a calibration site with a maximum frequency of 18 GHz;

 

1kW amplifier, 80 MHz to 1 GHz;

 

250W amplifier, 1 GHz to 18 GHz;

 

500W amplifier, 10 kHz to 200 MH;

 

5M EMC laboratory - capable of conducting tests from 26 MHz to 18 GHz. Can be used for testing according to the following standards: SAE, ISO, General Motors, Ford, Chrysler, Nissan, Audi, Fiat, Honda, Mazda; CISPR 25111622SAE J1113SAE J551

 

General industrial standards, including automotive, General Motors 5097, 3100 DC 10614REV A Ford AB/AC Nissan, Mazda, Fiat, Honda, Audi, Chrysler SAEISO Mazda;

 

? Provides peripheral support tools: compressed air (125 PSI @ 30 CFM, coated or purified @ 2 microns, water (up to 100 PSI), external air outlet (200 CFM), AC power supply - maximum 240 VAC @ 50 Amps (50 or 60 Hz) single-phase or three-phase, DC power supply - maximum 65 VDC @ 150 Amps. Full color internal monitoring system, providing multiple camera angles. We can also provide generators, coolers, power loads, inert gases, and EMC enhanced computers.

 

EUT (Equipment Under Test) can be a desktop or floor standing device.

Scope

EN standard

IEC standard

Electrical Fast   Transient Pulse Swarm Immunity

EN 61000-4-4

IEC 801-4; IEC   61000-4-4

Conducted continuous interference from DC   to 150 kHz

EN 61000-4-16

IEC 61000-4-16

Conducted   interference induced by radio frequency field

EN 61000-4-6

IEC 61000-4-6

Electrostatic   Discharge

EN 61000-4-2

IEC 61000-4-2

General Immunity   - Industrial Environment

EN 61000-6-2

IEC 61000-6-2

General Immunity   - Residential, Commercial, and Light Industrial

EN 61000-6-1

IEC 61000-6-1

Magnetic field,   damping oscillation wave

EN 61000-4-10

IEC 61000-4-10

Magnetic field,   ringing wave

EN 61000-4-12

IEC 61000-4-12

Power frequency   magnetic field

EN 61000-4-8

IEC 61000-4-8

Pulse magnetic   field

EN 61000-4-9

IEC 61000-4-9

Pulse magnetic   field

EN 61000-4-3

IEC 61000-4-3

surge

EN 61000-4-5

EN 61000-4-5

Voltage dip,   short interruption, and voltage variation

EN 61000-4-11

IEC 61000-4-11

Standard Number Standard Name

DB33/T334 Safety Technology Prevention (System) Engineering Inspection Specification

GB 16796 Safety Requirements and Test Methods for Security Alarm Equipment

GB 50339 Code for Quality Acceptance of Intelligent Building Engineering

GB 50348 Technical Specification for Security and Prevention Engineering

GB 8702 Electromagnetic Radiation Protection Regulations

GB 9175 Environmental Electromagnetic Wave Health Standard

GB/T 12190 Measurement Method for Shielding Efficiency of Electromagnetic Shielding Room

GB/T 15541 Measurement Method for Transmitting Frequency

GB/T 2887 General Specification for Computer Sites

SJ/T 10694 Test Method for Anti static Systems in Electronic Product Manufacturing

 

 

Please consult NormalTCI for specific questions

National Unified Service Hotline: 400-6177-880

Email service@normaltci.com

Copyright @ 2015 NORMAL (HANGZHOU) TESTING & CERTIFICATION CO., LTD.  

Tell:+86-571-28906690  E-mail:service@normaltci.com  Service Hotline:400-6177-880  Fax:+86-571-28867000

If you have any comments on the website, please email to:service@normaltci.com